resistivity-ip-dcip-survey-properties
schema/components/resistivity-ip-dcip-survey-properties/1.0.0/resistivity-ip-dcip-survey-properties.schema.json
Survey properties specific to Direct Current Induced Polarization (DCIP) resistivity-IP surveys. DCIP measures the voltage decay after a current injection is switched off, characterising the chargeability of the subsurface. This is the most common IP survey type in mineral exploration.
Used by: resistivity-ip.
See also: resistivity-ip-phaseip-survey-properties, resistivity-ip-sip-survey-properties, resistivity-ip-pldp-configuration-properties, resistivity-ip-plpl-configuration-properties.
Properties
resistivity-ip-dcip-survey-properties (v1.0.0)
Resistivity-IP properties for Direct Current Induced Polarization (DCIP) surveys.
| Property | Type | Description | Flags |
|---|---|---|---|
| type | String | Type of survey. | ✅ |
| delay_time | Number | Delay time (sec). Integration start time since current shut off. | ✅ |
| duty_cycle | Number | Time (sec) cycle. | |
| number_of_time_gates | Integer | Number of time gates. | ✅ |
| gate_times | Number | Width of each IP time (sec) gate. | ✅ |
| wave_type | Integer | Wave type. 50% or 100% duty cycle. | |
| pulses | Integer | Number of pulses. |
Legend
| Flag | Description |
|---|---|
| ⬆️ | Inherited property |
| ✅ | Required property |